Full-scale testing and numerical modelling of segmental-joint performance with corroded bolt

Dong-Mei Zhang,Bing-Li Zhang,Tai-Lai Luo,Dong-Ming Zhang,Bao-Jun Li
DOI: https://doi.org/10.1016/j.tust.2021.104260
IF: 6.9
2022-01-01
Tunnelling and Underground Space Technology
Abstract:Water leakage through segmental joints often occurs for shield tunnels built under groundwater. Chloride ions in groundwater can cause the corrosion of steel bolts in segmental joints, reducing the rigidity of the tunnel lining and endanger the operation safety of tunnels. In this paper, the impact of the corrosion of the steel bolt on the structural performance of segmental joint was investigated using six full-scale segmental joint tests and a series of numerical simulation. Both the experimental and numerical results indicate that the segmental-joint performance can be divided into three stages under different loading and corrosion states. The bolt corrosion can reduce the waterproof ability, bending stiffness, and ultimate bearing capacity of the segmental joint. The impact of the bolt corrosion is most significant in the second stage. Furthermore, the bolt corrosion has a larger impact on segmental-joint performance under a positive bending moment than under a negative bending moment, owing to the configuration of the joint. The impact of the bolt corrosion is strongly dependent on the loading state of the tunnel joint and the corrosion ratio of the bolt.
construction & building technology,engineering, civil
What problem does this paper attempt to address?