The use of radiography for thickness measurement and corrosion monitoring in pipes

K. Edalati,N. Rastkhah,A. Kermani,M. Seiedi,A. Movafeghi
DOI: https://doi.org/10.1016/j.ijpvp.2006.07.010
IF: 2.56
2006-10-01
International Journal of Pressure Vessels and Piping
Abstract:In this study of pipes of 150mm diameters, thickness ranging from 4.2 to 15.0mm was determined by using two radiography techniques: tangential radiography and double wall radiography. It was concluded that thickness losses of 10%, 20% and 50% could be determined by these methods. Formulae were developed for the double wall radiography method with a high precision of thickness measurement for non-insulated pipes. The precision was comparable with ultrasonic measurement results. Corrosion type and corrosion surface could be observed by these methods. Internal or external corrosion produced different effects in tangential radiography. Insulation removal was not necessary using the radiographic techniques.
engineering, mechanical, multidisciplinary