Self-Mixing Interferometer for Acoustic Measurements through Vibrometric Calibration

Simon Chanu-Rigaldies,Pierre Lecomte,Sébastien Ollivier,Thomas Castelain
DOI: https://doi.org/10.3390/s24061777
IF: 3.9
2024-03-10
Sensors
Abstract:The Self-Mixing Interformeter (SMI) is a self-aligned optical interferometer which has been used for acoustic wave sensing in air through the acousto-optic effect. This paper presents how to use a SMI for the measurement of Sound Pressure Level (SPL) in acoustic waveguides. To achieve this, the SMI is first calibrated in situ as a vibrometer. The optical feedback parameters C and α in the strong feedback regime (C≥4.6) are estimated from the SMI vibrometric signals and by the solving of non-linear equations governing the SMI behaviour. The calibration method is validated on synthetic SMI signals simulated from SMI governing equations for C ranging from 5 to 20 and α ranging from 4 to 10. Knowing C and α, the SMI is then used as an acoustic pressure sensor. The SPLs obtained using the SMI are compared with a reference microphone, and a maximal deviation of 2.2 dB is obtained for plane waves of amplitudes ranging from 20 to 860 Pa and frequencies from 614 to 17,900 Hz. The SPL measurements are carried out for C values ranging from 7.1 to 21.5.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to perform sound pressure level (SPL) measurement through self - mixing interferometer (SMI) without using a reference microphone. Specifically, the goal of the paper is to establish an in - situ calibration method to estimate two key parameters, the linewidth enhancement factor \(\alpha\) of the laser diode and the feedback factor \(C\), by solving the control equations of SMI. These parameters are crucial for the application of SMI in acoustic waveguides under the strong - feedback regime. ### Background Traditional optical interferometers are very useful in mechanical and acoustic metrology, but they require precise alignment of optical components to generate interference fringes. This alignment process can be very cumbersome in practical applications and is easily subject to external interference. In contrast, the self - mixing interferometer (SMI) is a self - aligning interferometer, consisting of only two elements: a laser diode (LD) and a photodiode (PD). SMI measures vibration or acoustic pressure changes by detecting the optical feedback signal in the cavity of the laser diode. ### Problem Description Although there have been some studies on the application of SMI in acoustic waveguides, most of them rely on a reference microphone for in - situ calibration. This method limits the advantages of SMI over using a microphone alone. Therefore, this paper aims to develop an in - situ calibration method without a reference microphone, especially to estimate the linewidth enhancement factor \(\alpha\) and the feedback factor \(C\) by solving the control equations of SMI. ### Solution To achieve this goal, the paper proposes the following steps: 1. **Calibration**: - **Vibration Measurement**: Generate a known vibration signal through a vibrator. SMI measures these vibration signals and records a signal \(U_{\text{cal}}\) containing discontinuities. - **Discontinuity Detection**: Detect discontinuities from \(U_{\text{cal}}\) and calculate the average values \(U^{\pm}_{\text{cal}}\) and \(bU^{\pm}_{\text{cal}}\) before and after the discontinuities. - **Parameter Estimation**: Estimate the values of \(U_0\), \(\upsilon\), \(C\) and \(\alpha\) by solving a set of nonlinear equations (see equation (17)). 2. **Acoustic Measurement**: - **Acoustic Signal Measurement**: Turn off the vibrator, turn on the speaker, generate an acoustic wave signal of a known frequency, and SMI measures these acoustic wave signals and records \(U_{\text{ac}}\). - **Phase Calculation**: Calculate the phase \(\Phi\) from \(U_{\text{ac}}\) using \(U_0\) and \(\upsilon\). - **Optical Path Calculation**: Calculate the optical path \(L\) from \(\Phi\) using \(C\) and \(\alpha\). - **Sound Pressure Estimation**: Assuming plane - wave propagation, estimate the sound pressure \(p'\) from \(L\). ### Experimental Verification The paper experimentally verifies the effectiveness of the above - mentioned method. The experimental results show that this method can accurately estimate the sound pressure level under different values of \(C\) and \(\alpha\), with a maximum deviation of 2.2 dB, and is applicable to the case where the plane - wave amplitude ranges from 20 to 860 Pa and the frequency ranges from 614 to 17,900 Hz. ### Conclusion This paper proposes an SMI in - situ calibration method without a reference microphone, which estimates the key parameters \(C\) and \(\alpha\) by solving the control equations of SMI. The experimental results verify the effectiveness of this method, providing new possibilities for the application of SMI in acoustic waveguides.