Flexible humidity sensor based on crosslinked polyethyleneimine/tannic acid and porous carbonaceous interdigitated electrode

Hongyan He,Yanbo Yao,Tao Liu
DOI: https://doi.org/10.1016/j.snb.2023.134194
2023-06-28
Abstract:For their advantages of flexibility in nature, low cost, and ease of processing, polymers and polymer composites are considered to be ideal candidates for the development of wearable and flexible humidity sensors. Nevertheless, the commonly adopted polymer-based humidity sensing materials are usually subjected to long-term stability issue, due to a lack of chemically crosslinked network structure. Herein, we rely on the robust Michael addition reaction between polyethyleneimine (PEI) and tannic acid (TA) in aqueous solution for fabricating the chemically crosslinked TA-x-PEI based humidity sensors through a simple spray coating process . With assistance of direct laser writing carbonization (DLWc) technique, we demonstrate that the combination of TA-x-PEI with porous carbon interdigitated electrode (PC-IDE) allows for facile fabrication of high-performance flexible humidity sensors, which possess fast response and recovery performance (28 s/12 s), low hysteresis (2%) in the range of 35% RH - 90% RH, good long-term stability (impedance change < 2% over 30 days) and high sensitivity, as demonstrated by a comparison of key metrics with similar humidity sensors reported in the literature. SEM microscopy, Raman and FTIR spectroscopy, frequency-dependent impedance measurement, as well as equivalent circuit modeling have been performed to gain an in-depth understanding of the humidity sensing behavior and the underlying mechanism for the newly developed PC-IDE enabled TA-x-PEI based humidity sensors.
chemistry, analytical,electrochemistry,instruments & instrumentation
What problem does this paper attempt to address?
The problems that this paper attempts to solve mainly focus on two aspects: 1. **Improving the long - term stability of humidity sensors**: The paper points out that traditional polymer - based humidity - sensing materials, due to the lack of a chemically cross - linked network structure, are prone to chain - segment dissolution, migration or relaxation in a high - humidity environment, thus leading to long - term stability problems. Especially in wearable and flexible electronic devices, this mechanical deformation will further exacerbate this problem. Therefore, the paper proposes to improve the long - term stability of humidity sensors by using materials with a chemically cross - linked network structure. 2. **Improving the performance of humidity sensors**: In order to improve the performance of humidity sensors, especially key indicators such as sensitivity, response time, recovery time and hysteresis, the paper proposes a new sensor design method. Specifically, the paper utilizes polyethyleneimine (PEI) and tannic acid (TA) to form chemically cross - linked TA - x - PEI materials through the Michael addition reaction, and combines porous carbon interdigital electrodes (PC - IDE) prepared by direct laser writing carbonization technology (DLWc) to achieve high - performance flexible humidity sensors. ### Specific solutions: - **Material selection and modification**: - Use PEI and TA to form chemically cross - linked TA - x - PEI materials through the Michael addition reaction, enhancing the stability and mechanical properties of the materials. - Optimize the cross - linking density by adjusting the ratio of TA to PEI, thereby balancing the sensitivity and stability of the sensor. - **Electrode preparation**: - Utilize the direct laser writing carbonization technology (DLWc) to prepare porous carbon interdigital electrodes (PC - IDE) on a polyimide (PI) film, improving the conductivity and porous structure of the electrodes, increasing the contact area of water molecules, and thus improving the sensitivity of the sensor. - **Sensor performance evaluation**: - Characterize the structure and performance of TA - x - PEI materials by means of scanning electron microscopy (SEM), Raman spectroscopy (Raman) and Fourier transform infrared spectroscopy (FTIR). - Measure the impedance change of the sensor under different humidity conditions by an impedance analyzer to evaluate its performance indicators such as sensitivity, response time, recovery time and hysteresis. ### Main achievements: - **High - performance sensors**: - The prepared PC - IDE - based TA - x - PEI humidity sensor exhibits fast response (28 seconds) and recovery (12 seconds), low hysteresis (2%) and good long - term stability (impedance change less than 2% within 30 days). - The sensor shows high sensitivity in the relative humidity range from 35% to 90%, and its performance is better than other similar sensors reported in the literature. Through the above methods, the paper has successfully solved the deficiencies of traditional polymer - based humidity sensors in long - term stability and performance, providing new ideas and technical solutions for the development of high - performance wearable and flexible humidity sensors.