Efficiency of shear connectors under combined shear and torsion

Masood Farzam Mohammad Amin Jahanian Hamed Sadaghian Faculty of Civil Engineering,University of Tabriz,Tabriz,Iran
DOI: https://doi.org/10.1080/15376494.2024.2392617
2024-08-20
Mechanics of Advanced Materials and Structures
Abstract:The connection of steel elements to concrete is typically achieved through embedded shear connectors (anchors) placed at the interface of concrete and steel. These shear connectors come in various types, such as headed studs, welded or coupled rebars, shear lugs, or a combination of these, designed to handle large shear forces. Shear connectors primarily resist shear forces and bending loads. However, when the load is not applied along the centroid of the shear connector, it generates a torsional moment in addition to shear- and flexure-induced moments, impacting the performance of shear connectors. To address this phenomenon, this experimental study assesses the behavior of shear connectors, including studs, shear lugs, and rebars, both individually and in combination, under three different load eccentricities relative to anchors spacing connectors (0, 0.25, 0.50, and 0.75). The results are then compared with the control specimen (without eccentricity). The findings revealed that vertical shear lugs can significantly enhance the shear capacity, and ACI 318-19 is conservative in this regard by 41.5% for a relative load eccentricity of 0.75. Nonetheless, it gives good estimations of the shear capacity of connectors without vertical shear lugs.
materials science, multidisciplinary,mechanics, composites, characterization & testing
What problem does this paper attempt to address?