Osmotic-induced cleaning is effective in long-term fouling mitigation of reverse osmosis elements at pilot plant level

Ammar Alnumani,Asif Matin,M. Farooque,T. Green,W. Falath,Isam Aljundi,Atia Khalifa,Mizanur Rahman,Tahar Laoui,Abdulrahman Abutaleb
DOI: https://doi.org/10.1016/j.desal.2024.117336
IF: 11.211
2024-01-17
Desalination
Abstract:Osmotic backwashing (OBW), a promising environment-friendly membrane cleaning technique, has been mostly studied at the lab scale. In this work, we investigated the efficacy of periodic OBW in fouling mitigation at a pilot-plant level. After initial optimization of the major OBW parameters, it was applied periodically to a single-element RO module used for seawater desalination. The continuous monitoring of major performance parameters and comparison to a control unit revealed the success of periodic OBW in fouling mitigation: significantly lower feed channel pressure (FCP) drop (50–100 kPa vs. 200 kPa), less decline in normalized permeate flow (10 % vs. 30 %), and virtually unaffected salt rejection (99.5 % vs. 99.2 %). Findings from foulant analyses and membrane autopsy correlated well with the filtration results: fouling layer on the backwashed membrane was less dense and had a lower inorganic content (~57 %) compared to the control (~72 %), and two important properties, the surface roughness (~160 vs. 270 nm) and zeta potential (−18 vs. −10 mV) witnessed a smaller increase. In summary, OBW was quite effective in mitigating fouling and its effects on membrane performance.
engineering, chemical,water resources
What problem does this paper attempt to address?