Abstract:In the frame of a research project, the structural behaviour in fire of cross-laminated timber rib panels were studied based on numerical investigations. The floor system consists of cross-laminated timber plates rigidly bonded to glued-laminated timber ribs. The numerical investigations comprised uncoupled thermo-mechanical simulations of two types of finite element models, a beam system and a flexible-in-shear multi-layered part, to investigate the influence of the effective width in fire. All models were validated against the experimental results of previously tested full-scale fire resistance tests. A parametric study analysed the composite cross‐sections' effective width in fire for a parameter range expected in practice and gave proposals depending on the thickness of the CLT layers. For the conservative case of thin CLT layers, a limit value of 60% of the effective width at normal temperature is proposed as effective width in fire.
materials science, multidisciplinary,engineering
What problem does this paper attempt to address?