Experimental research on fire safety of lightweight bamboo frame buildings

Xiao Yan,Ma Jian,Shan Bo,Chen Guo,She Liyong
2012-01-01
Abstract:A fire simulation test of full-scale room unit was carried out to study the fire safety of lightweight bamboo frame buildings.Firewood with its quantity determined based on European standard was stacked and ignited in the testing room unit.After an hour fire,the maximum charring depth of glue laminated bamboo(Glubam) studs was only 1/3 of the sectional dimension under the protection of 9.5mm ordinary gypsum board,and the floor beams were scarcely damaged under the protection of 19mm fire-resistant gypsum board.The house maintained a good structural integrity at the end of fire test,demonstrating the satisfactory fire resistance of the lightweight bamboo frame building system.Based on instrumentation of 8 pairs of thermocouples installed on the surface of walls and floor,the highest temperature of internal surface was recorded as 686℃,while the highest temperature of external surface was in the range of 46℃ to 84℃,indicating the good thermal insulation using the gypsum boards and rockwool.On the basis of the experimental research,fire design measures were suggested for the new bamboo building system.
What problem does this paper attempt to address?