Aseismic Performance Tests for a Light Glubam House

CHEN Guo,SHAN Bo,XIAO Yan
DOI: https://doi.org/10.3969/j.issn.1000-3835.2011.10.026
2011-01-01
Abstract:To study aseismic behavior of a lightweight bamboo frame residential house,shake table tests were conducted using a full-scale model simulating a first floor room unit of a typical two-storey house,with the size of 2.44m multiplied by 3.66m in plane and 2.6m in height.Earthquake-lateral-resistance was provided by glubam shear walls around the perimeter of the model.The test results indicated that the model is in the elastic state and has essentially no visual damage for 0.3g PGA.The tested glubam house could withstand under action of three different seismic ground motions within a range of 0.5g PGA without collapse.The observed damage remained noncritical for 0.5g PGA.Inter-story drift in the first storey was below the limited values in most codes.After shaked with 0.5g PGA,the model was retested under a pushover loading condition and the result showed its sufficient deformability.The tests revealed that the glubam house can meet the requirements of the seismic intensity of 8° described in Chinese aseismic design code.
What problem does this paper attempt to address?