Shaking table tests of Chinese traditional wood building and light wood framed building

王海东,尚守平,何放龙,黄曙,邓涛,刘冬柏
DOI: https://doi.org/10.14006/j.jzjgxb.2012.06.006
2012-01-01
Abstract:By shaking table tests of two 1∶ 2 scaled prototype structures,the seismic performance of Chinese traditional wood building and light wood framed building were studied.The results show that under the horizontal earthquake action whose peak value is less than 0.5g,the horizontal acceleration responses at the top of columns of Chinese traditional wood building can be less than the acceleration input.The dynamic magnification factor of acceleration ranges from 0.46 to 0.57.The corresponding displacements can be larger than the displacement input.When the peak value of the input acceleration is bigger than 0.4g,the obvious slippage between the columns and base-stones,as well as the deflection of joints connecting beams and columns will appear.As the result,the energy of the earthquake can be dissipated and the excellent effect of shock absorption can be achieved.Furthermore,for the light wood framed building,when the peak value of the input acceleration is bigger than 0.4g,the dynamic magnification factor of acceleration can be bigger than 1.0.And if the peak value of input acceleration is not more than 0.5g,the light wood framed building can remain elastic.