Characterization of Transition Edge Sensors for Decay Energy Spectrometry

Carlson, Max
DOI: https://doi.org/10.1007/s10909-024-03135-9
2024-05-17
Journal of Low Temperature Physics
Abstract:By using a superconducting transition edge sensor (TES) to measure the thermal energy of individual decay events with high energy resolution, decay energy spectrometry provides a unique fingerprint to identify each radionuclide in a sample. The proposed measurement requires optimizing the thermal parameters of the detector for use with 5 MeV scale energy deposited by alpha decay of the sample radionuclides. The thermal performance of deep-etched silicon TES chips is examined with the use of an onboard resistive heater. With known heater power and bath temperature, the thermal conductance, heat capacity, and frame temperature are calculated and compared to theory.
physics, condensed matter, applied
What problem does this paper attempt to address?
This paper aims to solve the technical challenges encountered in decay energy spectrometry (DES) using superconducting transition - edge sensors (TES). Specifically, the paper focuses on optimizing the thermal parameters of the detector so that it can effectively measure the thermal energy of single decay events of radionuclides in samples, especially when the energy of these events is on the order of 5 MeV. To achieve this goal, the researchers conducted a detailed thermal performance analysis of TES chips with deep - etched silicon structures. Using on - chip resistive heaters, they calculated and compared the differences between the thermal conductivity, heat capacity, and frame temperature and their theoretical values under known heating power and bath temperature. The paper solves the above problems through the following points: 1. **Optimizing Thermal Links**: The thermal conductivities from the TES island to the TES frame and from the frame to the bath temperature were studied to ensure that high - energy pulses (about 1 pJ) can be completed quickly within 50 ms, which requires higher thermal conductivity and corresponding bias power. 2. **Thermal Parameter Measurement**: A resistive heater and a second TES located on the TES frame were used to measure the thermal impedance from the TES island to the frame and then to the bath temperature, and the temperature of the TES frame and the heat capacity of the TES island during operation were calculated by fitting the heat flow model. 3. **Experimental Verification**: Through a series of experiments, the validity of the theoretical model was verified, and various factors affecting the efficiency of thermal links, such as the electron - phonon coupling strength, the acoustic mismatch between the Si substrate and the Au pad, etc., were explored. In summary, this research aims to improve the detection ability and accuracy of TES in high - energy decay events by precisely controlling and optimizing its thermal performance, thereby providing technical support for the direct, absolute, and comprehensive determination of small amounts of radionuclides. This is of great significance for safety, environmental monitoring, medicine, and electronics and other fields.