Fast geometric distortion correction using a deep neural network: Implementation for the 1 Tesla MRI‐Linac system

Mao Li,Shanshan Shan,Shekhar S. Chandra,Feng Liu,Stuart Crozier
DOI: https://doi.org/10.1002/mp.14382
IF: 4.506
2020-08-02
Medical Physics
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Purpose</h3><p>Combining high‐resolution magnetic resonance imaging (MRI) with a linear accelerator (Linac) as a single MRI‐Linac system provides the capability to monitor intra‐fractional motion and anatomical changes during radiotherapy, which facilitates more accurate delivery of radiation dose to the tumour and less exposure to healthy tissue. The gradient non‐linearity (GNL) induced distortions in MRI; however, hinder the implementation of MRI‐Linac system in image‐guided radiotherapy where highly accurate geometry and anatomy of the target tumour is indispensable.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Methods</h3><p>To correct the geometric distortions in MR images, in particular, for the 1 Tesla (T) MRI‐Linac system, a deep fully‐connected neural network was proposed to automatically learn the intricate relationship between the undistorted (theoretical) and distorted (real) space. A data set, consisting of spatial samples acquired by phantom measurement that covers both inside and outside the working diameter of spherical volume (DSV), was utilised for training the neural network; which offers the ability to describe subtle deviations of the GNL field within the entire region of interest (ROI).</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>The performance of the proposed method was evaluated on MR images of a three‐dimensional (3D) phantom and the pelvic region of an adult volunteer scanned in the 1T MRI‐Linac system. The experimental results showed that the severe geometric distortions within the entire ROI had been successfully corrected with an error less than the pixel size. Also, the presented network is highly efficient, which achieved significant improvement in terms of computational efficiency compared to existing methods.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Conclusions</h3><p>The feasibility of the presented deep neural network for characterising the GNL field deviations in the 1T MRI‐Linac system was demonstrated in this study, which shows promise in facilitating the MRI‐Linac system to be routinely implemented in real‐time MRI‐guided radiotherapy.</p></section>
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?