ReUINet: A fast GNL distortion correction approach on a 1.0 T MRI‐Linac scanner

Shanshan Shan,Mao Li,Mingyan Li,Fangfang Tang,Stuart Crozier,Feng Liu
DOI: https://doi.org/10.1002/mp.14861
IF: 4.506
2021-04-20
Medical Physics
Abstract:<section class="article-section__content"><h3 class="article-section__sub-title section1"> Purpose</h3><p>The hybrid system combining a magnetic resonance imaging (MRI) scanner with a linear accelerator (Linac) has become increasingly desirable for tumour treatment because of excellent soft‐tissue contrast and non‐ionising radiation. However, image distortions caused by gradient non‐linearity (GNL) can have detrimental impacts on real‐time radiotherapy using MRI‐Linac systems, where accurate geometric information of tumours is essential.</p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Methods</h3><p>In this work, we proposed a deep convolutional neural network‐based method to efficiently <b>re</b>cover <b>u</b>ndistorted <b>i</b>mages (<i>ReUINet</i>) for real‐time image guidance. The <i>ReUINet</i>, based on the encoder‐decoder structure, was created to learn the relationship between the undistorted images and distorted images. The <i>ReUINet</i> was pre‐trained and tested on a publically available brain MR image dataset acquired from 23 volunteers. Then, transfer‐learning was adopted to implement the pre‐trained model (i.e., network with optimal weights) on the experimental 3D grid phantom and <i>in‐vivo</i> pelvis image datasets acquired from the 1.0 T Australian MRI‐Linac system. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Results</h3><p>Evaluations on the phantom (768 slices) and pelvis data (88 slices) showed that the <i>ReUINet</i> achieved over 15‐times and 45‐times improvement on computational efficiency in comparison with standard interpolation and GNL‐encoding methods, respectively. Moreover, qualitative and quantitative results demonstrated that the <i>ReUINet</i> provided better correction results than the standard interpolation method, and comparable performance compared to the GNL‐encoding approach. </p></section><section class="article-section__content"><h3 class="article-section__sub-title section1"> Conclusions</h3><p>Validated by simulation and experimental results, the proposed <i>ReUINet</i> showed promise in obtaining accurate MR images for the implementation of real‐time MRI‐guided radiotherapy. </p></section>
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?