Ground shock attenuation performances of wire-rope-based meta-isolators

Yang Liu,Dongyu Shi,Yu Li,Sanfeng Liu,Huguang He,Hailong Chen,Hualin Fan
DOI: https://doi.org/10.1016/j.tws.2023.111538
IF: 5.881
2024-01-03
Thin-Walled Structures
Abstract:In this research, two types of novel meta-isolators were designed based on traditional wire-rope isolators and made by embedding mass-spring resonators into the wire-rope isolator. Measurement methods to reveal attenuation abilities of these meta-isolators were suggested through quasi-static cyclic loading tests, shaking table tests, and in-field explosion experiments. In the quasi-static tests, meta-isolators have greater hysteresis area under the same excitation displacement, which represents much greater energy consumption. Using shaking table tests and measurement, the vibration attenuation ability of the meta-isolators is improved in the designed resonant frequency, and the response amplitudes are significantly reduced compared with the conventional wire-rope isolators. Blast-induced ground shock experiments reveal that the meta-isolators indeed have an advantage over the conventional isolators in the aspect of shock resistance and the attenuation efficiency exceeds 98 %, providing a new idea and reference for protective engineering.
engineering, mechanical,mechanics, civil
What problem does this paper attempt to address?