Experimental study on seismic performance of modular cast-in-situ coupled shear wall with LRC infill wall
Hao Chen,Chao Yang,Jinping Ou,Baojun Zhao,Chao Li,Cong Li
DOI: https://doi.org/10.1016/j.jobe.2023.106613
IF: 7.144
2023-01-01
Journal of Building Engineering
Abstract:With the sweeping adoption of prefabrication in the construction industry, there is increasing attention on study and practice in exploring modular construction technology. The use of modular construction technology is widespread in low-rise buildings and is gaining popularity in multistory high-rise buildings. Current applications of modular construction for high-rise buildings are limited because of the lack of strong structural systems and joining techniques to ensure the structural integrity, overall stability, and robustness of an entirely modular building. This study proposes a new concrete modular structure system that is suitable for frame structures, frameshear wall structures, and shear wall structures. The concrete modular structure is characterized in that all the structural elements are cast in situ, and the modular units not only act as permanent formworks but also work together structurally with cast-in-situ concrete. The walls of the precast module consist of lightly reinforced concrete (LRC) infill walls and thin concrete wall formworks. Quasi-static cyclic loading tests were conducted on seven concrete modular cast-insitu coupled shear walls with LRC infill walls. The seismic performance of the specimens, including the initial stiffness, bending capacity, ductility, and energy dissipation, was evaluated in detail, and the effects of different infill wall types and connection methods with structural elements on the seismic performance of modular cast-in-situ structures were compared. The results indicate that the LRC infill walls significantly affect the seismic performance of the specimen, particularly the initial stiffness, maximum lateral load-bearing capacity, and failure modes. The specimens without an LRC infill wall exhibited failure at a 1/40 drift ratio, while the specimens with an LRC infill wall failed at a drift ratio of 1/60 or below. At a 1/1000 drift ratio, the secant stiffness of the specimens is increased by 3.7 times and 4.5 times respectively for the flexible and rigid connection of LRC infill walls. Full consideration of the significant stiffnessincreasing effect and deformation-limiting effect of the LRC infill wall and its connection methods with the structural elements is important to achieve a better design of the new concrete modular structure.