Optimal Design of Sparse Matrix Phased Array Using Simulated Annealing for Volumetric Ultrasonic Imaging with Total Focusing Method

Dmitry Olegovich Dolmatov,Vadim Yurevich Zhvyrblya
DOI: https://doi.org/10.3390/s24061856
IF: 3.9
2024-03-14
Sensors
Abstract:The total focusing method (TFM) is often considered to be the 'gold standard' for ultrasonic imaging in the field of nondestructive testing. The use of matrix phased arrays as probes allows for high-resolution volumetric TFM imaging. Conventional TFM imaging involves the use of full matrix capture (FMC) for ultrasonic signals acquisition, but in the case of a matrix phased array, this approach is associated with a huge volume of data to be acquired and processed. This severely limits the frame rate of volumetric imaging with 2D probes and necessitates the use of high-end equipment. Thus, the aim of this research was to develop a novel design method for determining the optimal sparse 2D probe configuration for specific conditions of ultrasonic imaging. The developed approach is based on simulated annealing and involves implementing the solution of the sparse matrix phased array layout optimization problem. In order to implement simulated annealing for the aforementioned task, its parameters were set, the acceptance function was introduced, and the approaches were proposed to compute beam directivity diagrams of sparse matrix phased arrays in TFM imaging. Experimental studies have shown that the proposed approach provides high-quality volumetric imaging with a decrease in data volume of up to 84% compared to that obtained using the FMC data acquisition method.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The paper attempts to address the problem of optimizing the design of sparse matrix phased arrays in volumetric ultrasound imaging using the simulated annealing algorithm. Specifically: - **Background and Challenges**: In the field of Non-Destructive Testing (NDT), the Full Matrix Capture (FMC) method combined with the Total Focusing Method (TFM) is considered the "gold standard" for ultrasound imaging. However, when using matrix phased arrays for high-resolution volumetric TFM imaging, the traditional FMC method results in a large amount of data acquisition and processing workload, which limits the frame rate of 2D probes and requires high-end equipment support. - **Research Objective**: Therefore, the goal of this paper is to develop a new design method to determine the optimal sparse 2D probe configuration for ultrasound imaging under specific conditions. This method is based on the simulated annealing algorithm and aims to solve the optimization problem of sparse matrix phased array layout. - **Main Contribution**: By introducing the acceptance function, calculating the beam steering map of the sparse matrix phased array in TFM imaging, and setting the simulated annealing parameters, this method can reduce the data volume by up to 84% while ensuring high-quality volumetric imaging, which has significant advantages over the traditional FMC data acquisition method.