Adaptive Total Focusing Method for Ultrasonic Full-Matrix Imaging of Anisotropic CFRP Laminates
Zhenyang Yu,Haoran Jin,Jian Chen
DOI: https://doi.org/10.1088/1742-6596/2822/1/012127
2024-01-01
Journal of Physics Conference Series
Abstract:Abstract The application of total focusing method (TFM) for imaging of Carbon fiber reinforced plastics (CFRP) with ultrasonic phased array is particularly challenging due to the layered structure and anisotropy of CFRP. To improve the TFM imaging performance, the precise knowledge of complex ultrasonic paths in anisotropic CFRP laminates should be obtained for accurate calculation of time of flights (TOFs), which makes the inspection process complicated and time-consuming. In this work, an adaptive TFM is developed for full-matrix imaging of CFRP laminates using ultrasonic phased array. Based on the acquired full matrix data, the elastic constants, including C 11, C 22, C 55, and C 13, can be directly derived using TOFs of A-scan signals. Based on the measured elastic constants, group velocity profiles of quasi-pressure (QP) wave were then calculated for different stacking sequences, from which the TOFs were corrected. To verify the effectiveness of proposed method, simulations and experiments are demonstrated on the CFRP laminates with different stacking sequences. As a representative example, the delamination defects are showcased. Compared with isotropic TFM, the SNR of proposed method is increased by 10.2-18.0 dB. The simulated and experimental results agreed well with each other, indicating that the feasibility of proposed method in full matrix imaging of anisotropic CFRPs.