Improved Total Focusing Method ( ITFM ) for ultrasonic imaging of thick walled welds based on ray-tracing algorithm

ZHOU Haipeng,HAN Zandong,DU Dong,CHEN Yifang
2018-01-01
Abstract:Thick walled welds are widely applied in key components of nuclear reactors. Ultrasonic imaging is one of the most commonly used Non-Destructive Evaluation (NDE) technique for thick walled welds, which helps to identify and locate the defects. Total Focusing Method (TFM) is a useful technique to generate images based on a matrix of ultrasonic signals. The signal matrix can be acquired by a transducer array using Full Matrix Capture (FMC) technique. The application of traditional imaging methods often leads to deviations, as the materials are considered as isotropic ones. Improved Total Focusing Method (ITFM) is developed for ultrasonic imaging of thick walled welds, in order to have the anisotropy taken into consideration. The ultrasonic propagation is estimated by an efficient ray-tracing algorithm mainly derived from Dijkstra algorithm. The propagation paths can be acquired by minimizing the propagation time between two selected points, based on Fermat’s principle. In this way, the time-of-flight of each pixel in an ITFM image can be calculated. To evaluate the imaging performance, a simulation model was established, consisting of the isotropic base material and the anisotropic weld. The ultrasonic field of the model was calculated by a multi-Gaussian beam modeling method, which was further utilized to generate the FMC signal matrix for imaging. TFM and ITFM images were generated and their imaging performances were compared and discussed.
What problem does this paper attempt to address?