Investigating the Association between Motor Function, Neuroinflammation, and Recording Metrics in the Performance of Intracortical Microelectrode Implanted in Motor Cortex
Evon S. Ereifej,Youjun Li,Monika Goss-Varley,Youjoung Kim,Seth M. Meade,Keying Chen,Jacob Rayyan,He Feng,Keith Dona,Justin McMahon,Dawn Taylor,Jeffrey R. Capadona,Jiayang Sun
DOI: https://doi.org/10.3390/mi11090838
IF: 3.4
2020-09-03
Micromachines
Abstract:Long-term reliability of intracortical microelectrodes remains a challenge for increased acceptance and deployment. There are conflicting reports comparing measurements associated with recording quality with postmortem histology, in attempts to better understand failure of intracortical microelectrodes (IMEs). Our group has recently introduced the assessment of motor behavior tasks as another metric to evaluate the effects of IME implantation. We hypothesized that adding the third dimension to our analysis, functional behavior testing, could provide substantial insight on the health of the tissue, success of surgery/implantation, and the long-term performance of the implanted device. Here we present our novel analysis scheme including: (1) the use of numerical formal concept analysis (nFCA) and (2) a regression analysis utilizing modern model/variable selection. The analyses found complimentary relationships between the variables. The histological variables for glial cell activation had associations between each other, as well as the neuronal density around the electrode interface. The neuronal density had associations to the electrophysiological recordings and some of the motor behavior metrics analyzed. The novel analyses presented herein describe a valuable tool that can be utilized to assess and understand relationships between diverse variables being investigated. These models can be applied to a wide range of ongoing investigations utilizing various devices and therapeutics.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is related to the long - term reliability of intracortical microelectrodes (IMEs). Specifically, the author focuses on the relationships between IME implantation and motor function, neuroinflammation, and recording quality. The main objective of the paper is to evaluate the relationships among electrophysiological, histological, and motor performance indicators by introducing numerical formal concept analysis (nFCA) and regression analysis methods, in order to better understand the long - term performance and tissue response after IME implantation.
The paper mentions that although IME technology has achieved many successes in helping patients with neurological diseases and spinal cord injuries to use mind - controlled computer cursors, robotic arms, and even their own limbs, its wide clinical application is still limited by the difficulty in maintaining stable long - term recordings. This inconsistency and overall decline in recording performance have been observed in animal models in multiple laboratories, including humans. A major obstacle is electrode instability due to chronic inflammatory responses, which can affect the survival rate of neurons and the degradation of device materials. However, few studies have been able to find the association between IME performance and the neuroinflammatory response caused by the implanted device. Therefore, this paper attempts to analyze the effects after IME implantation from multiple dimensions by combining electrophysiological recordings, histological evaluations, and behavioral tests, hoping to provide a basis for future research.