Microstructure and Physico-Mechanical Properties of Biocompatible Titanium Alloy Ti-39Nb-7Zr after Rotary Forging

Anatoly Illarionov,Galymzhan Mukanov,Stepan Stepanov,Viktor Kuznetsov,Roman Karelin,Vladimir Andreev,Vladimir Yusupov,Andrei Korelin
DOI: https://doi.org/10.3390/met14050497
IF: 2.695
2024-04-25
Metals
Abstract:The evolution of microstructure, phase composition and physico-mechanical properties of the biocompatible Ti-39Nb-7Zr alloy (wt.%) after severe plastic deformation by rotary forging (RF) was studied using various methods including light optical microscopy, scanning and transmission electron microscopies, X-ray diffraction, microindentation, tensile testing and investigation of thermophysical properties during continuous heating. The hot-rolled Ti-39Nb-7Zr with initial single β-phase structure is subjected to multi-pass RF at 450 °C with an accumulated degree of true deformation of 1.2, resulting in the formation of a fibrous β-grain structure with imperfect 500 nm subgrains characterized by an increased dislocation density. Additionally, nano-sized α-precipitates formed in the body and along the β-grain boundaries. These structural changes resulted in an increase in microhardness from 215 HV to 280 HV and contact modulus of elasticity from 70 GPa to 76 GPa. The combination of strength and ductility of Ti-39Nb-7Zr after RF approaches that of the widely used Ti-6Al-4V ELI alloy in medicine, however, Ti-39Nb-7Zr does not contain elements with limited biocompatibility and has a modulus of elasticity 1.5 times lower than Ti-6Al-4V ELI. The temperature dependences of physical properties (elastic modulus, heat capacity, thermal diffusivity) of the Ti-39Nb-7Zr alloy after RF are considered and sufficient thermal stability of the alloy up to 450 °C is demonstrated.
materials science, multidisciplinary,metallurgy & metallurgical engineering
What problem does this paper attempt to address?
The main purpose of this paper is to study the effects of multi-pass Rotary Forging (RF) on the microstructure, phase composition, and physical-mechanical properties of the biocompatible titanium alloy Ti-39Nb-7Zr. Specifically, the paper aims to address the following issues: 1. **Changes in microstructure**: How does the microstructure of the alloy change after rotary forging treatment? Particularly, the grain structure of the β phase and the characteristics of subgrains. 2. **Changes in phase composition**: Are new phases formed during the rotary forging process? Especially the formation of α precipitates. 3. **Changes in physical-mechanical properties**: How do the physical-mechanical properties such as hardness and elastic modulus of the alloy change after rotary forging treatment? 4. **Comparison with existing materials**: Compare the Ti-39Nb-7Zr alloy after rotary forging treatment with the widely used medical alloy Ti-6Al-4V ELI to evaluate the performance differences. Through these studies, the paper aims to develop a new titanium alloy with better biocompatibility and lower elastic modulus to meet the needs of orthopedic implants.