Comparative Study of the Adhesion Properties of Ceramic Composite Separators Using a Surface and Interfacial Cutting Analysis System for Lithium-Ion Batteries

Hyunkyu Jeon,Junyoung Choi,Myung-Hyun Ryou,Yong Min Lee
DOI: https://doi.org/10.1021/acsomega.7b00493
IF: 4.1
2017-05-17
ACS Omega
Abstract:Because of the constantly increasing demand for highly safe lithium-ion batteries (LIBs), interest in the development of ceramic composite separators (CCSs) is growing rapidly. Here, an in-depth study of the adhesion properties of the Al<sub>2</sub>O<sub>3</sub> ceramic composite coating layer of CCSs is conducted using a peel test and a surface and interfacial cutting analysis system (SAICAS). Contrary to the 90 and 180° peel tests, which resulted in different adhesion strengths even for the same CCS sample, the SAICAS is able to measure the adhesion properties uniformly as a function of depth from the surface of the coating layer. The adhesion strengths measured at the midlayer (<i>F</i> <sub>mid</sub>) and interface (<i>F</i> <sub>inter</sub>, interlayer between the separator and the ceramic coating layer) are compared for various types of CCS samples with different amounts of polymeric binder, and it is found that <i>F</i> <sub>inter</sub> is higher than <i>F</i> <sub>mid</sub> for all CCSs. Compared with <i>F</i> <sub>mid</sub>, <i>F</i> <sub>inter</sub> is significantly affected by storage in the liquid electrolyte (under wet condition).
chemistry, multidisciplinary
What problem does this paper attempt to address?