Numerical study on a novel thermal management system coupling immersion cooling with cooling tubes for power battery modules

Zhiyang Zou,Jiekai Xie,Yunjun Luo,Guoqing Zhang,Xiaoqing Yang
DOI: https://doi.org/10.1016/j.est.2024.110634
IF: 9.4
2024-02-03
Journal of Energy Storage
Abstract:Immersion cooling (IC) has been treated as the most potential alternative to replace traditional liquid cooling (LC) systems for battery thermal management because of its simple structure and high cooling efficiency. However, the flowing oil-based immersion fluid requires an extra circulation system apart from the vehicle thermal management systems (VTMS), inevitably increasing the energy consumption and reducing the integration level. Herein, we propose a novel LC system coupling static IC with LC tubes (LCTs). The heat generated by the cells can be absorbed by the static immersion fluid, and dissipated rapidly by the water-based fluid in LCTs directly connecting to the VTMS. The results show that by adopting ten LCTs with an inlet velocity of 0.2 m·s −1 , the maximum temperature and temperature difference can be controlled below 43.3 °C and 2.62 °C under the ambient temperature of 25 °C, and below 55.72 °C and 3.51 °C under the ambient temperature of 40 °C, respectively. Besides these comparable cooling performances with the existing IC systems, which require extra flowing oil-based fluid circulations, the separately-installed LCTs in this newly-designed IC system are allowed to connect to the circulation of the VTMS directly, thus greatly enhancing the integration level of the vehicles.
energy & fuels
What problem does this paper attempt to address?