SCFs for CHS-to-CHS T- and X-type moment-loaded end connections: Proposal for formulae

Ali Ziaeinejad,Kyle Tousignant,Min Sun,Zhiyuan Yang
DOI: https://doi.org/10.1016/j.jcsr.2024.108734
IF: 4.349
2024-05-03
Journal of Constructional Steel Research
Abstract:The research presented in this paper is part of a series of efforts to develop design recommendations for hollow structural section (HSS) connections situated at the end of a truss (or frame) under fatigue loading. Full-sized circular hollow section (CHS)-to-CHS regular and end connections (with open chord ends and chord-end cap plates) were tested under branch in-plane bending to measure strain concentrations at the critical locations. This experimental data was then used to verify a finite element (FE) modelling approach. An FE parametric study (totaling 1120 FE models, including 560 T-type connections and 560 X-type connections) was then carried out to investigate the effects of different chord end boundary conditions (i.e., varied chord end lengths, and open versus cap-plated chord ends). The effects of branch-to-chord width ( β ), chord slenderness (2 γ ) ratios and branch-to-chord thickness ( τ ) were also investigated. It was found that the stress concentration factors (SCFs) in end connections are sensitive to the boundary conditions (i.e., open chord end versus with chord-end cap plate) and all three non-dimensional parameters ( β , 2γ and τ ). Therefore, SCF correction factors based on e / b 0 , β , 2γ and τ , are derived for use with existing SCF formulae in CIDECT Design Guide 8.
engineering, civil,construction & building technology
What problem does this paper attempt to address?