Quantitative MRI for Monitoring Metabolic Dysfunction‐Associated Steatotic Liver Disease: A Test–Retest Repeatability Study

Cayden Beyer,Anneli Andersson,Elizabeth Shumbayawonda,Naim Alkouri,Ami Banerjee,Prashant Pandya,Mukesh Harisinghani,Kathleen Corey,Andrea Dennis,Michele Pansini
DOI: https://doi.org/10.1002/jmri.29610
IF: 4.4
2024-09-27
Journal of Magnetic Resonance Imaging
Abstract:Background Quantitative magnetic resonance imaging metrics iron‐corrected T1 (cT1) and liver fat from proton density fat‐fraction (PDFF) are both commonly used as noninvasive biomarkers for metabolic dysfunction‐associated steatohepatitis (MASH); however, their repeatability in this population has rarely been characterized. Purpose To quantify the variability of cT1 and liver fat fraction from PDFF in patients with biopsy‐confirmed metabolic dysfunction‐associated steatotic liver disease (MASLD) and MASH. Study Type Prospective, single center. Population Twenty‐one participants (female = 11, mean age 53 ± 24 years) with biopsy‐confirmed MASLD, including 6 with MASH and fibrosis ≥2. Field Strength/Sequence 3 T; T1 and T2* mapping for the generation of cT1 (shMOLLI: CardioMaps and 2D MDE, T1map‐FIESTA and LMS MOST: StarMap, 2D Multi‐Echo FSPGR) and magnitude‐only PDFF sequence for liver fat quantification (LMS IDEAL: StarMap, 2D Multi‐Echo FSPGR). Assessment T1 mapping and PDFF scans were performed twice on the same day for all participants (N = 21), with an additional scan 2–4 weeks later for MASH patients with fibrosis ≥2 (N = 6). Whole liver segmentation masks were generated semi‐automatically and average pixel counts within these masks were used for the calculation of cT1 and liver fat fraction. Statistical Tests Bland–Altman analysis for repeatability coefficient (RC) and 95% limits of agreement (LOA) and intraclass correlation coefficient (ICC). Results Same‐day RC was 32.1 msec (95% LOA: −36.6 to 24.2 msec) for cT1 and 0.6% (95% LOA: −0.5% to 0.7%) for liver fat fraction; the ICCs were 0.98 (0.96–0.99) and 1.0, respectively. Short‐term RC was 65.2 msec (95% LOA: −63.8 to 76.5 msec) for cT1 and 2.6% (95% LOA: −2.8% to 3.1%) for liver fat fraction. Data Conclusion In participants with MASLD and MASH, cT1 and liver fat fraction measurements show excellent test–retest repeatability, supporting their use in monitoring MASLD and MASH. Level of Evidence 2 Technical Efficacy Stage 2
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?