Research on the Sealing Mechanism of Split-Liner High-Pressure Hydrogen Storage Cylinders

Guxing Tong,Xiaolei Zhu,Yang Liu,Fuxiang Lv,Xiaofeng Lu
DOI: https://doi.org/10.3390/pr12030554
IF: 3.5
2024-03-13
Processes
Abstract:Hydrogen storage is a crucial factor that limits the development of hydrogen energy. This paper proposes using a split liner for the inner structure of a hydrogen storage cylinder. A self-tightening seal is employed to address the sealing problem between the head and the barrel. The feasibility of this structure is demonstrated through hydraulic pressure experiments. The influence laws of the O-ring compression rate, the distance from the straight edge section of the head to the sealing groove, and the thickness of the head on the sealing performance of gas cylinders in this sealing structure are revealed using finite elements analysis. The results show that when the gas cylinder is subjected to medium internal pressure, the maximum contact stress on the O-ring extrusion deformation sealing surface is greater than the medium pressure. There is sufficient contact width, that is, the arc length of the part where the stress on the O-ring contact surface is greater than the medium pressure, so that it can form a good sealing condition. At the same time, increasing the compression ratio of the O-ring and the head's thickness will help improve the sealing performance, and reducing the distance from the straight edge section of the head to the sealing groove will also improve the sealing performance.
engineering, chemical
What problem does this paper attempt to address?
The paper aims to address the sealing issue of the split structure of the liner in high-pressure hydrogen storage tanks. Specifically: - **Research Background**: Hydrogen storage is one of the key factors limiting the development of hydrogen energy. Existing hydrogen storage tanks (such as Type I, II, III, and IV) each have their advantages and disadvantages, but common issues include low hydrogen storage efficiency, high weight-to-capacity ratio, and hydrogen embrittlement. - **Main Problem**: For Type III and IV tanks, their liners are usually made of metal or polymer materials and are combined with a composite outer layer. However, these designs face sealing challenges at the joints between the head and the cylinder, especially since polymer liners are prone to aging and mechanical performance degradation, making it difficult to achieve good sealing. - **Solution**: The paper proposes a new split liner structure that addresses the sealing issue between the head and the cylinder using a self-tightening sealing principle. Specifically, a sealing groove is set on the straight edge section of the head, and an O-ring is used as the sealing element to achieve reliable sealing. - **Experimental Verification**: The feasibility of this structure was verified through hydraulic pressure experiments, and finite element analysis was conducted to explore the influence of factors such as O-ring compression rate, the distance from the straight edge section of the head to the sealing groove, and the thickness of the head on the sealing performance. In summary, the main purpose of this paper is to design a new type of split liner sealing structure and verify its effectiveness through experiments and simulations, thereby improving the safety and reliability of high-pressure hydrogen storage tanks.