Hydrogen peroxide detection with quartz-enhanced photoacoustic spectroscopy using a distributed-feedback quantum cascade laser

Wei Ren,Wenzhe Jiang,Nancy P. Sanchez,Pietro Patimisco,Vincenzo Spagnolo,Chung-en Zah,Feng Xie,Lawrence C. Hughes,Robert J. Griffin,Frank K. Tittel
DOI: https://doi.org/10.1063/1.4863955
IF: 4
2014-01-27
Applied Physics Letters
Abstract:A quartz-enhanced photoacoustic spectroscopy sensor system was developed for the sensitive detection of hydrogen peroxide (H2O2) using its absorption transitions in the v6 fundamental band at ∼7.73 μm. The recent availability of distributed-feedback quantum cascade lasers provides convenient access to a strong H2O2 absorption line located at 1295.55 cm−1. Sensor calibration was performed by means of a water bubbler that generated titrated average H2O2 vapor concentrations. A minimum detection limit of 12 parts per billion (ppb) corresponding to a normalized noise equivalent absorption coefficient of 4.6 × 10−9 cm−1W/Hz1/2 was achieved with an averaging time of 100 s.
physics, applied
What problem does this paper attempt to address?