Abstract:In this paper, a distributed parameter model for the evaporation system of a subcritical once-through, coal-fired, twin-furnace boiler based on 3-D temperature field reconstruction is developed. The imaginary wall surface was put forward to simplify the twin-furnace problem. The mathematical model was formulated for predicting the transient distributions of parameters, such as the heat flux, the metal-surface temperature and the steam quality; while considering the non-uniform distributions of the surface heat transfer coefficient and frictional resistance coefficient. The model was based on the 3-D temperature distribution got by a flame image processing technique. The model was validated by some measurable parameters of the evaporation system at three typical loads. The results show that the heat flux and the temperature which are located at the overlapping region of the two tangential flames are higher than those in other corners. This distributed parameter model on evaporation system reflects the in-situ operating status of the power plant boiler, which may lead to the subsequent research on a supercritical boiler.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?