Proton-Transfer-Reaction Mass Spectrometry for Rapid Dynamic Measurement of Ethylene Oxide Volatilization from Medical Masks

Runyu Wang,Yunhe Zhang,Leizi Jiao,Xiande Zhao,Zhen Gao,Daming Dong
DOI: https://doi.org/10.3390/atmos15010114
IF: 3.11
2024-01-19
Atmosphere
Abstract:Sterile medical masks are essential in preventing infectious diseases. However, the ethylene oxide contained within these masks is a class I carcinogen. The standard method for measuring ethylene oxide is gas chromatography-mass spectrometry, which is not fit with the dynamic process of human inhalation. Thus, the amount of ethylene oxide volatilized from masks and inhaled by users is unknown. In this work, ethylene oxide was detected by using proton-transfer-reaction mass spectrometry, which can measure volatile quantities in milliseconds. We found that ethylene oxide was volatilized from masks during use. Within the first minute, the ethylene oxide concentration decreased by 84.65%, and then the rate of reduction gradually slowed. After 5 min, all ethylene oxide was effectively volatilized, and the average mass of ethylene oxide inhaled was 299.02 μg. We investigated three methods to reduce the concentration of ethylene oxide in masks before use: natural airing, shaking the mask, and blowing the mask with a hair dryer. The hair dryer method produced the best results: the ethylene oxide concentration decreased by 88.3% after only 10 s. The natural airing method was the least effective: the ethylene oxide concentration decreased by 60.7% even after 3 h.
environmental sciences,meteorology & atmospheric sciences
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to solve the following key problems: 1. **Dynamic measurement of ethylene oxide volatilization**: - Ethylene oxide (EO) is a class 1 carcinogen and is widely used for sterilizing medical masks. However, traditional detection methods such as gas chromatography - mass spectrometry (GC - MS) cannot monitor the volatilization of ethylene oxide in real - time during wearing. Therefore, the paper proposes to use proton - transfer - reaction mass spectrometry (PTR - MS) to achieve rapid dynamic measurement of the ethylene oxide volatilization amount. 2. **Evaluation of ethylene oxide inhalation amount**: - The paper experimentally measured the ethylene oxide volatilization of different brands of masks during wearing and calculated the total amount of ethylene oxide that the wearer may inhale. The results showed that most of the ethylene oxide had been inhaled within the first minute of wearing, which helps to assess the potential risks to human health of wearing masks. 3. **Methods to reduce ethylene oxide concentration**: - The paper explored three practical methods to reduce the ethylene oxide concentration in masks: natural ventilation, shaking the mask, and blowing the mask with a hair dryer. The study found that blowing the mask with a hair dryer had the best effect, reducing the ethylene oxide concentration by 88.3% in just 10 seconds; while natural ventilation had the worst effect, with the concentration only reduced by 60.7% even after 3 hours. ### Formula summary In order to accurately calculate the mass of ethylene oxide inhaled during wearing, the paper used the following formula: \[ EM = S\times V\div P \tag{1} \] where: - \( EM \) represents the mass of ethylene oxide inhaled by the human body when wearing a mask (unit: g) - \( S \) represents the rate of decrease in ethylene oxide concentration within time \( t \) (unit: ppbv/min) - \( V \) represents the amount of gas exhaled by the human body during calm breathing within time \( t \) (unit: L) - \( P \) represents the proportion of the decrease in ethylene oxide concentration in the mask within time \( t \) Further simplified as: \[ EM = S_t\times 6t\div P_t \tag{2} \] where: - \( S_t \) represents the change in ethylene oxide concentration in the mask at time \( t \) (unit: ppbv/min) - \( 6t \) represents the amount of gas inhaled at time \( t \) (unit: L) - \( P_t \) represents the proportion of the change in ethylene oxide concentration in the mask at time \( t \) to the initial concentration In addition, in order to evaluate the safe inhalation amount, the following formula was introduced: \[ EM_s = C\times 6t \tag{3} \] where: - \( EM_s \) represents the safe inhalation amount (unit: g) - \( C \) represents the upper limit of the safe concentration of ethylene oxide in the environment (unit: ppbv) - \( 6t \) represents the amount of gas breathed by the human body within time \( t \) (unit: L) ### Conclusion Through these studies, the paper not only provides an accurate measurement method for ethylene oxide volatilization amount, but also provides practical suggestions for reducing the risk of inhaling ethylene oxide when wearing masks. This is of great significance for improving the safety of masks and protecting public health.