The ring imaging Cherenkov detector for the BRAHMS experiment at RHIC

R. Debbe,S. Gushue,B. Moskowitz,J. Olness,F. Videbaek
DOI: https://doi.org/10.1016/0168-9002%2895%2901182-X
1997-06-17
Abstract:A ring imaging Cherenkov counter, to be read out by four 100-channel PMTs, is a key element of the BRAHMS experiment. We report here the most recent results obtained tested at the BNL AGS using several radiator gases, including the heavy fluorocarbon C4F10. Ring radii were measured for different particles (pions, muons, and electrons) for momenta ranging from 2 to 12 GeV/c employing pure C4F10 as radiator.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to design and verify an efficient Ring Imaging Čerenkov (RICH) detector for the BRAHMS experiment in order to achieve accurate identification of high - momentum charged particles. Specifically, the RICH detector needs to be able to distinguish different types of particles, such as pions, muons and electrons, etc., in the momentum range from 1 to 25 GeV/c. ### Problem Background The BRAHMS experiment aims to study the particles produced in gold - gold (Au - Au) collisions at the Relativistic Heavy Ion Collider (RHIC). The experiment measures the properties of these particles through two magnetic spectrometer arms. One of the key challenges is to accurately identify different particle species in the high - momentum range. To achieve this goal, the BRAHMS experiment combines a Time of Flight (TOF) array and Čerenkov counters for particle identification. ### Role of the RICH Detector The main function of the RICH detector is to identify high - momentum particles by measuring the ring - shaped images of Čerenkov light. Čerenkov light is generated when high - speed charged particles propagate in a medium, and its angle is related to the particle's velocity. By measuring the radius of these rings, the velocity and type of the particle can be inferred. ### Solution The paper describes in detail the design and testing process of the RICH detector, including the following aspects: 1. **Design Parameters**: - Use C4F10 as the radiating gas, with a refractive index \( n = 1.00185 \) (under the conditions of 20°C and 1.25 atm). - The focal length of the elliptical mirror is 1.5 meters, and it is rotated by 8 degrees to avoid interference from the direct particle flow. - Use an array composed of four Hamamatsu R - 4549 - 01 photomultiplier tubes (PMT) to detect Čerenkov light. 2. **Prototype Testing**: - Conducted prototype testing on the BNL AGS accelerator, using pure C4F10 as the radiating gas. - Tested pions, muons and electrons in different momentum ranges (2 to 12 GeV/c). - Verified the performance of the detector by fitting the radius of the ring and compared it with the theoretical calculation results. 3. **Performance Evaluation**: - The results show that the imaging and resolution capabilities of the detector are as expected, especially performing well in the high - momentum region. - The measured ring radius is consistent with the theoretical prediction, verifying the rationality of the detector's design. ### Summary Through detailed experimental data and theoretical analysis, the paper proves that the designed RICH detector can effectively identify high - momentum charged particles and meet the requirements of the BRAHMS experiment. This provides a solid foundation for subsequent practical applications. ### Formula Examples - Refractive Index Formula: \[ n=\frac{c}{v} \] where \( c \) is the speed of light and \( v \) is the speed of light in the medium. - Ring Radius Formula: \[ r = \frac{f\cdot\sin{\theta_C}}{\sin{(\theta_C+\alpha)}} \] where \( f \) is the focal length of the mirror, \( \theta_C \) is the Čerenkov angle, and \( \alpha \) is the rotation angle of the mirror. Through these designs and tests, the paper successfully solves the problem of accurately identifying charged particles in the high - momentum range.