A gaseous RICH detector for SiD or ILD

Matthew J. Basso,Valentina M. M. Cairo,Chris Damerell,Dong Su,Ariel G. Schwartzman,Jerry Va'vra
DOI: https://doi.org/10.1016/j.nima.2023.168992
2023-12-09
Abstract:This paper describes a preliminary study of a gaseous Ring Imaging Cherenkov (RICH) system capable of discriminating between kaons and pions at high momenta -- up to 50 GeV/c -- and thus enhancing particle identification at future colliders. The system possesses a compact design, facilitating easy integration into existing detector concepts. A study of the key contributions to the Cherenkov angle resolution is also presented.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to effectively distinguish pions and kaons at high momenta (up to 50 GeV/c) in future colliders (such as the International Linear Collider, ILC). Specifically, the paper explores the design of a gaseous Ring - Imaging Cherenkov (RICH) detector, which can improve particle identification capabilities in the high - momentum range while maintaining a compact design for easy integration into existing detector concepts. ### Main research contents: 1. **Detector design**: - The detector uses gas as a radiator and distinguishes different types of particles by measuring the Cherenkov angle. - Silicon photomultipliers (SiPMs) are used as photon detectors in the design, and advanced timing techniques are introduced to reduce SiPM noise. 2. **Performance evaluation**: - The paper analyzes various factors that affect the Cherenkov angle resolution, including dispersion errors, pixel size errors, and focusing / defocusing errors. - Through simulation and calculation, the particle identification performance at different momenta is evaluated, especially the separation ability for pions and kaons. 3. **Optimization suggestions**: - Methods to further improve performance by optimizing the optical design, adjusting the orientation of the detector plane, and mirror parameters are proposed. - It is expected that future photon detector technologies will be significantly improved, thereby enhancing the performance of the entire system. ### Key formulas: - **Calculation of the number of photoelectrons**: \[ N_{\text{pe}} = N_0 L \sin^2(\langle \theta_c \rangle) \] where \( L \) is the length of the radiator, \( \langle \theta_c \rangle \) is the average Cherenkov angle, and \( N_0 \) is given by the following formula: \[ N_0 = \frac{\alpha \bar{h} c R}{\epsilon(E) \sin^2(\langle \theta_c \rangle)} \] where \( \alpha \) is the fine - structure constant, \( \bar{h} \) is the reduced Planck constant, \( c \) is the speed of light, \( R \) is the refractive index of the radiator, and \( \epsilon(E) \) is the detection efficiency. - **Calculation of particle separation**: \[ S = \frac{|\theta_\pi - \theta_K|}{\left( \frac{\sigma_{\theta_c}}{\sqrt{N_{\text{pe}}}} \right)} \] where \( \theta_\pi \) and \( \theta_K \) are the Cherenkov angles of pions and kaons respectively, \( \sigma_{\theta_c} \) is the single - photon Cherenkov angle resolution, and \( N_{\text{pe}} \) is the number of photoelectrons per ring. ### Conclusion: The paper shows that through optimized design and improved technology, effective distinction between pions and kaons at high momenta can be achieved in future colliders. This requires not only precise optical design and efficient photon detectors, but also excellent tracking angle resolution and low - noise levels. These improvements will help to enhance the physical research capabilities of future colliders.