Experimental investigation on combined flow and temperature non-uniformity for three-fluid compact heat exchanger with cross flow configuration

Harpreet Kaur Aasi,Manish Mishra
DOI: https://doi.org/10.1080/08916152.2024.2427703
2024-11-23
Experimental Heat Transfer
Abstract:Non-uniformities in flow and temperature are the most conspicuous reason behind diminishing efficacy in heat exchangers. Cross-flow three-fluid heat exchanger being a pivotal component in cryogenics, is experimentally investigated under imposed flow and temperature non-uniformities in central hot fluid. The interaction of combined flow and temperature non-uniformity invariably precipitates a degradation in the efficacy of both adjacent fluids. About 7.3% and 6.2% of efficacy degradation is encountered in fluid "a" (for C2 configuration) and fluid "c" (for C1 configuration), respectively, for FN1+TNIII model. In many cases, C1 configuration and TNIII model is inimical to fluid "c" performance.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?