Exposure frequency and radiation dose from CT examinations in Huaian

Binbin Huo,Xiaomin Chen,Zhiyong Xu,Dongdong He,Jin Wang
DOI: https://doi.org/10.1093/rpd/ncad302
2024-01-09
Radiation Protection Dosimetry
Abstract:Abstract This study quantified the exposure frequency and established the local diagnostic reference levels (DRLs) for the most common computed tomography (CT) examinations. A combined method census and sampling survey was used to quantify both frequency and radiation dose of CT examinations. Data were acquired through Picture Archiving and Communication System (PACS) or Radiology Information System (RIS). The annual frequency of CT examinations was 239.8 per 1000 inhabitants. The P75 of volume CT dose index (CTDIvol) to adult patients from CT scanning for head, chest, abdomen and lumbar spine examinations were 63.0, 12.4, 20.0 and 24.0 mGy, respectively. The P75 of dose-length product were 858.6, 416.0, 620.7 and 559.2 mGy·cm, respectively. This dose audit of CT practice can act as a starting point for establishing Huaian local DRLs and could be a reference for dose optimisation in China. This study compared DRLs in different countries and analysed some reasons for the rapid growth of CT examination frequency in Huaian.
environmental sciences,public, environmental & occupational health,radiology, nuclear medicine & medical imaging,nuclear science & technology