Scanning parameters analysis on pediatric CT examination

Ai-ping LAI,Xin-fa DING,Fang-qi GONG
DOI: https://doi.org/10.3969/j.issn.1006-9011.2006.05.024
2006-01-01
Journal of Medical Imaging
Abstract:Objective:To investigate whether adjustments related to patients age were made in the scanning parameters(mAs and kVp) that are determinants of radiation dose for multislice CT in pediatric patients and evaluate the indication of the pediatric CT examinations according to negative diagnosis.Methods:Two hundred and ninety-nine patients from 3 typical hospitals(pediatric hospital(Ⅰ),general hospital with pediatric department(Ⅱ),and adults hospital without pediatric department(Ⅲ)) were divided into three groups on the basis of individual's age: group A(0~3 years),group B(4~8 years) and group C(9~14 years);The mAs,kVp and diagnosis results are analysed.Results:51.8% of diagnosis results were negative.We found no evident of adjustment in mAs and kVp based on the ages of patients.The scan parameter mAs in hospital(Ⅲ) was significantly higher than that in hospital Ⅰ and hospital Ⅱ.Conclusion:① Fifty one point eight percent negative diagnosis results showed that the indication of pediatric CT examination was not strictly managed.②Pediatric multislice CT parameters(mAs and kVp) on head scan were not adjusted on the basis of the age of the children.Adults hospital need to improve scan parameters and reduce the radiation dose of pediatric CT examination.
What problem does this paper attempt to address?