Active vibration control for window rattling caused by infrasound: Field experiment for one pair of sliding glass doors installed on the test building

Keiichiro Iwanaga,Tetsuya Doi,Akira Omoto
DOI: https://doi.org/10.3397/in_2023_1036
2023-11-30
INTER-NOISE and NOISE-CON Congress and Conference Proceedings
Abstract:We developed an active vibration control system to reduce window vibration caused by infrasound since serious environmental noise problems such as window rattling have remained in Japan. In our previous study, we demonstrated the application of active noise control for the window vibration to reduce the transmitted sound into the room by using the low-frequency sound generator as the secondary source. However, active noise control using sound waves has the problem of increasing the sound pressure level in some areas outside the control window. Therefore, we developed an active vibration control system equipped with self-made inertial vibration exciters and laser displacement gauges to reduce the window vibration caused by infrasound without increasing the sound pressure level. An experiment was conducted to investigate the applicability of the developed active vibration control system to reduce window vibration. The vibration of one pair of sliding glass doors installed in the test building was controlled by the developed systems mounted on windows so that vibration displacement became static. As a result, the displacement of window vibration caused by infrasound was reduced by one-third without increasing the sound pressure level outside the test building. This vibration reduction resulted in the transmitted sound into the room by up to 11 dB within the frequency range below 16Hz.