Geotechnical seismic isolation based on high-damping polyurethane: centrifuge modelling

Hing-Ho Tsang,Duc-Phu Tran,Wen-Yi Hung,Emad F. Gad
DOI: https://doi.org/10.1007/s10518-023-01842-4
IF: 4.556
2024-01-11
Bulletin of Earthquake Engineering
Abstract:Geotechnical seismic isolation (GSI) is a new category of low-damage resilient design methods that are in direct contact with geomaterials and of which the isolation mechanism primarily involves geotechnics. Various materials have been explored for placing around the foundation system in layer form to facilitate the beneficial effects of dynamic soil-foundation-structure interaction, as one of the GSI mechanisms. To reduce the thickness of the GSI foundation layer and to ensure uniformity of its material properties, the use of a thin and homogeneous layer of high-damping polyurethane (HDPU) was investigated in this study via centrifuge modelling. HDPU sheets were installed in three different configurations at the interface between the structural foundation and surrounding soils for realising GSI. It was found that using HDPU for GSI can provide excellent seismic isolation effects in all three configurations. The average rates of structural demand reduction amongst the eight earthquake events ranged from 35 to 80%. A clear correlation between the period-lengthening ratio and the demand reduction percentage can be observed amongst the three GSI configurations. One of the configurations with HDPU around the periphery of the foundation only is particularly suitable for retrofitting existing structures and does not require making changes to the structural systems or architectural features.
geosciences, multidisciplinary,engineering, geological
What problem does this paper attempt to address?
The problem this paper attempts to address is the reduction of structural demands (such as acceleration, strain, etc.) on buildings during earthquakes by using High-Damping Polyurethane (HDPU) as a seismic isolation material, thereby improving the seismic performance of buildings. Specifically, the study aims to explore whether HDPU, as part of a Geotechnical Seismic Isolation (GSI) system in different configurations, can effectively reduce the impact of earthquakes on buildings, and whether this material can be used as a thin and uniform layered material for new buildings or the retrofitting of existing buildings to achieve better seismic isolation. The paper tests three different HDPU configuration schemes through centrifuge model tests, namely: 1. **C1 Configuration**: HDPU is continuously laid around the entire foundation. 2. **C2a Configuration**: HDPU is laid only around the foundation perimeter, with the foundation bottom in contact with natural soil. 3. **C4 Configuration**: HDPU is laid under the foundation, leaving gaps around the foundation. The study found that using HDPU as a GSI material can significantly reduce the structural demands on buildings during various seismic events. The C1 configuration can reduce structural demands by an average of 35% to 80%, the C2a configuration by an average of 30% to 40%, and the C4 configuration by an average of 55% to 85%. Additionally, the study observed a clear correlation between the natural period elongation ratio and the percentage reduction in demands, indicating that the seismic isolation effect of HDPU in different configurations is closely related to its impact on the system's natural period. Particularly, the C2a configuration is considered especially suitable for retrofitting existing buildings due to its adaptability and the fact that it does not require changes to the structural system or building characteristics.