Single-Phase APFC Technique Applied to Aviation Power Supply

Song Guo-cui
Abstract:Single-phase boost PFC converter has been widely used in industry due to its high power factor and high efficiency.But the input current distortion in the vicinity of input voltage zero crossing becomes very serious at airborne line frequency of 360 Hz-800 Hz,the current harmonic content is difficult to meet the RTCA DO-160D standards proposed by the aviation system.Therefore,the traditional PFC control system design cannot meet the requirements of airborne power supply.This paper introduces several different control methods and a topology to improve the input current zero-crossing distortion,and gives the corresponding circuit and methods,and point out respective advantages and disadvantages.By comparing these three methods,leading-phase admittance cancellation(LPAC) is the suitable method in engineering application,and based on control chip UCC3817,designed a laboratory prototype,experimental results show the feasibility of LPAC method.
Engineering
What problem does this paper attempt to address?