Effects of Zirconium on mechanical and electrochemical properties of Ti-15mo alloy for biomedical applications

Haydar H. J. Jamal Al-Deen,Jassim M. S. Al-Murshdy,Shahad R. Huseein
DOI: https://doi.org/10.1063/5.0148028
2023-01-01
AIP Conference Proceedings
Abstract:The Ti-15Mo Alloy is a desirable source for usage as a biomaterial due to its outstanding corrosion resistance and a strong balance of mechanical qualities such as hardness, elastic modulus, and wear resistance. Zr additions were made in this work at four distinct weight-percentages 0.5,1.1.5, &2 3wt %). Powder metallurgy was used to create the alloys in a steel mold, followed by 6 hours of sintering at 950 °C. The influence of Zr alloy additions was studied using scanning electron microscopy(SEM), X-ray diffraction (XRD), corrosion behavior in Hank’s solutions, and mechanically such as (compression strength, hardness, wear, and elastic modulus). The alloys’ structure with β phase has better mechanical properties than titanium due to strengthening solid solution. The hardness results indicate an improvement of up to 37%, while the compressive strength has reached a 65% from the base alloy. The results revealed that the wear loss was significantly improved as the Zr was added and the corrosion current and corrosion rate was drastically reduced.
What problem does this paper attempt to address?