Experimental evaluation of airlift pumps' thermal and mass transfer capabilities
Alexander Doucette,Shahriyar G. Holagh,Wael H. Ahmed
DOI: https://doi.org/10.1016/j.expthermflusci.2024.111174
IF: 3.2
2024-03-02
Experimental Thermal and Fluid Science
Abstract:Airlift pumps are a versatile category of two-phase flow equipment principally employed for the transportation of liquids. Facilitating interfacial heat and mass transfer between gas and liquid phases, these pumps have the potential to serve as an efficient heat and mass exchanger in various industrial applications. Nonetheless, this capability of airlift pumps has remained relatively unexplored in the existing literature; therefore, present study aims at experimentally characterizing sensible heat and evaporative mass transfer performance of airlift pumps. In this study, a series of experiments were conducted using an airlift pump with a riser pipe diameter of 25.4 mm and a submergence ratio of 70 %; air and water were utilized as the gas and liquid phases, respectively. The experiments were performed under both isothermal and non-isothermal two-phase flow conditions; the gas temperature ranged from 22 °C to 110 °C, and the inlet air flow rate varied from 0.43 to 5.12 kg/hr . Instantaneous void fraction data were collected using a capacitance sensor and underwent evaluation through both Probability Density Function (PDF) and Power Spectral Density (PSD) statistical analysis. These analyses were coupled with flow visualization results obtained from high-speed imaging to analyze the two-phase flow hydrodynamics quantitatively and qualitatively. The study identified three flow patterns (slug flow, intermittent flow, and churn flow), and detected notable transformations in elongated bubbles and the formation of small bubble clusters and aerated regions. It was also found that churn flow exhibits the highest delivered liquid flow rate, while slug flow demonstrates the best lifting efficiency under both operational conditions. Also, the pump displayed notably higher lifting efficiencies under isothermal operation compared to non-isothermal one. Moreover, both sensible heat and evaporative mass transfer revealed improved performance with increasing inlet air flow rate, reaching maximum coefficients in the churn flow regime. Gas temperature in the present range found to have negligible effect on the two-phase interfacial structures, flow pattern transition, and delivered liquid flow rate, but a considerable positive impact on void fraction, lifting efficiency, and heat and mass transfer coefficients under non-isothermal operation.
engineering, mechanical,thermodynamics,physics, fluids & plasmas