Template‐aided and freehand guiding plane preparation for removable partial dentures: A randomized controlled trial

Hefei Bai,Hongqiang Ye,Kenan Ma,Sukun Tian,Hu Chen,Yong Wang,Yongsheng Zhou,Yuchun Sun
DOI: https://doi.org/10.1111/jopr.13948
2024-09-23
Journal of Prosthodontics
Abstract:Purpose To evaluate the accuracy of guiding plane preparation for removable partial dentures (RPDs) using 3D‐printed templates compared to the freehand method. Materials and Methods Twenty partially edentulous patients requiring RPDs were randomly divided into two groups: the template‐aided group (n = 10) and the freehand group (n = 10). Fifty‐six guiding planes were prepared by a single clinician using two different methods. The angle deviation between the prepared guiding plane and the RPD path of placement was measured for both groups. The 3D deviations between the prepared guiding plane and the designed guiding plane were measured for the template‐aided group. Patient satisfaction with the RPD was evaluated 2 weeks post‐RPD wearing. Results The angular deviation observed in the template‐aided group (1.77±1.11 degrees) was significantly lower than that (6.29±4.18 degrees) in the freehand group (p
dentistry, oral surgery & medicine