Effects of internal pressure and heating rate on the burst behaviors of Cr-coated cladding during simulated LOCA testing

Zhengang Duan,Bo Yuan,Qinglong Wen,Ruiqian Zhang,Kang Chen
DOI: https://doi.org/10.1016/j.anucene.2024.110548
IF: 1.9
2024-04-20
Annals of Nuclear Energy
Abstract:After more than 10 years of technical exploration, Chromium (Cr) coated zirconium cladding has become the main technical route of the accident tolerant fuel claddings (ATF). To investigate the effects of initial internal pressure and heating rate on the burst behavior of Cr-coated cladding under LOCA, the burst tests were conducted with Cr-coated zirconium alloy cladding in thickness of about 15 μm under 2–8 MPa initial internal pressure and heating rates of 1 °C/s and 15 °C/s in simulated LOCA environment. The burst temperature, burst pressure, and opening geometry were analyzed. The burst temperature for different initial internal pressures and heating rates were obtained, and the functional relationship between burst stress and burst temperature was also found. Under the same internal pressure, higher heating rate leads to higher burst temperature and lower burst strain.
nuclear science & technology
What problem does this paper attempt to address?