Fabrication of a Three-Dimensional Microfluidic System from Poly(methyl methacrylate) (PMMA) Using an Intermiscibility Vacuum Bonding Technique

Shu-Cheng Li,Chao-Ching Chiang,Yi-Sung Tsai,Chien-Jui Chen,Tien-Hsi Lee
DOI: https://doi.org/10.3390/mi15040454
IF: 3.4
2024-03-29
Micromachines
Abstract:In this study, the fabrication of microfluidic chips through the bonding of poly (methyl methacrylate) (PMMA) boards featuring designed patterns to create a three-dimensional sandwich structure with embedded microchannels was explored. A key focus was optimization of the interface quality of bonded PMMA pairs by adjusting the solvent, such as such as acetone, alcohol, and their mixture. Annealing was conducted below 50 °C to leverage the advantages of low-temperature bonding. Because of the differences in the chemical reactivity of PMMA toward acetone, alcohol, and their combinations, the resulting defect densities at the bonding interfaces differed significantly under low-temperature annealing conditions. To achieve the optimal sealing integrity, bonding pressures of 30 N, 40 N, and 50 N were evaluated. The interface was analyzed through microstructural examination via optical microscopy and stress measurements were determined using digital photoelasticity, while the bonding strength was assessed through tensile testing.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to optimize the manufacturing process of polymethyl methacrylate (PMMA) microfluidic chips, especially to improve the bonding quality by developing a new immiscible vacuum bonding technique. Specifically, the research focuses on: 1. **Optimizing the quality of the PMMA bonding interface**: By adjusting the proportion and type of solvents (such as acetone, alcohol and their mixtures), optimize the bonding quality between PMMA plates, thereby reducing the defect density and improving the sealing integrity. 2. **Achieving low - temperature bonding**: Bond at a temperature lower than 50 °C to take advantage of low - temperature bonding and avoid the influence of high temperature on the material structure. 3. **Evaluating the effects of different bonding pressures**: By testing the bonding pressures of 30 N, 40 N and 50 N, evaluate the changes in bonding strength and micro - channel microstructure under different pressure conditions. 4. **Comprehensive analysis of the bonding effect**: Through optical microscopy, digital photoelastic analysis and tensile testing, comprehensively evaluate the microstructure and mechanical properties of the bonding interface to ensure the reliability and durability of the bonding. ### Key issues - **Solvent selection and proportion optimization**: How to select appropriate solvents and their proportions to achieve the best bonding effect. - **Feasibility of low - temperature bonding**: Achieve effective bonding at a lower temperature while ensuring the integrity and functionality of the material. - **Influence of bonding pressure**: The specific influence of different bonding pressures on the bonding strength and the microstructure of the micro - channel. - **Microstructure analysis of the bonding interface**: Through various characterization methods, deeply understand the microstructure changes of the bonding interface and their influence on the overall performance. ### Solutions The author systematically studied the influence of different solvent combinations and bonding conditions on the PMMA bonding effect through a series of experiments. The research results show that using a 1:1 ratio of alcohol and acetone mixed solvents and a bonding pressure of 30 N can achieve the best bonding effect, with high bonding strength and fewer defects. In addition, low - temperature bonding conditions (below 50 °C) are helpful to maintain the integrity and functionality of the material. ### Conclusion This research provides important technical support for the efficient manufacturing of PMMA microfluidic chips, especially making significant progress in optimizing the bonding process. These achievements not only improve the performance and reliability of microfluidic devices, but also lay a solid foundation for the future development of microfluidic technology.