Influence of concrete cover and transverse reinforcement on residual post-fire bond performance of reinforcement in concrete

Josipa Bošnjak,Arunita Das,Akanshu Sharma
DOI: https://doi.org/10.1016/j.engstruct.2024.118191
IF: 5.582
2024-06-09
Engineering Structures
Abstract:The realistic consideration of reusability of a fire effected RC structure or structural member relies on the accurate estimation of post-fire structural capacity. Bond between steel and concrete play a vital part in the structural analysis of RC. This paper presents a study on bond behaviour of RC structural members exposed to fire employing ISO-834 fire scenario and using beam-end test specimens to take into account the realistic boundary conditions of a flexural member. The study is a continuation of the previous work done by authors. The focus of this paper is to understand the residual bond behaviour considering various concrete covers and the presence of transverse reinforcement for various fire durations. Two different fire exposure scenarios are considered, namely one-sided heating, where only the surface with the minimum concrete cover is exposed to fire and three-sided heating, where two side surfaces along with the surface with minimum cover are exposed to fire. The beam-end specimens were exposed to fire for a desired fire exposure duration, followed by a natural cooling to room temperature. An unconfined pull-out test was performed thereafter to obtain residual behaviour. The results show that although concrete cover and presence of transverse reinforcement do have an influence on the absolute values of the residual bond splitting strength after fire, the relative values of bond degradation due to fire are not very strongly influenced by these parameters.
engineering, civil
What problem does this paper attempt to address?