Localised corrosion failure of an L245N pipeline in a CO2–O2–Cl− environment

Jihui Leng,Zhiyuan Tian,Kexi Liao,Tengjiao He,Xin Liu,Guoxi He,Xin Tang,Guoqiang Xia
DOI: https://doi.org/10.1080/1478422X.2023.2188637
2023-03-18
Abstract:Multicomponent thermal fluid flooding has become a widely used and very effective heavy-oil recovery technology, but the harsh CO 2 –O 2 –Cl − environment can lead to serious corrosion perforation failure of the pipeline. Therefore, the influence of O 2 content and main controlling factors on corrosion perforation were investigated through a weight-loss experiment, corrosion defect test, characterization and grey correlation method. The results showed that, with the increase in O 2 content, the general corrosion rate and localized corrosion rate increased. The uneven protection performance of the product after the addition of O 2 was found to be the key cause of localized corrosion. In addition, the synergistic effect of O 2 –Cl − promoted the lateral and longitudinal expansion of pits. The results of the grey correlation showed that the temperature (30–120 °C) had a greater impact on localized corrosion compared with the content of O 2 (0–0.045 MPa) and Cl − (0–16,000 mg/L).
materials science, multidisciplinary,metallurgy & metallurgical engineering
What problem does this paper attempt to address?