Robot‐assisted total knee arthroplasty system provides more precise control of the femoral rotation angle: A retrospective study

Peng Yan,Xudong Duan,Yutian Lei,Fangze Xing,Ruomu Cao,Sen Luo,Yang Chen,Zeyu Liu,Kunzheng Wang,Pei Yang,Run Tian
DOI: https://doi.org/10.1002/rcs.2635
2024-05-13
International Journal of Medical Robotics and Computer Assisted Surgery
Abstract:Abstract Background Rotational alignment in total knee arthroplasty (TKA) is a crucial technical point that needs attention. We conducted a retrospective study to investigate whether a new robot‐assisted TKA (RA‐TKA) could improve the accuracy of rotational alignment and whether rotational alignment affects postoperative pain and functional evaluation of the knee. Methods A total of 136 consecutive patients who underwent TKA were included in this study. Half of the patients underwent RA‐TKA and the other half underwent conventional TKA (CON‐TKA) by the same group of surgeons. Collect the relevant parameters. Results The postoperative femoral rotation angle (FRA) was −0.72 ± 2.59° in the robot‐assisted group and 1.13 ± 2.73° in the conventional group, and were statistically significantly different ( p < 0.001). Conclusion This study provides preliminary evidence that the RA‐TKA provides more precise control of FRA than CON‐TKA, and verifies that tibial rotation angle and combined rotation angle affect postoperative knee pain and functional evaluation.
surgery
What problem does this paper attempt to address?