Error Correction Method of Sensor Based on Fuzzy-KF for Measurement of Drilling Cuttings

Haibo Liang,Haifeng Chen,Jinhong Guo,Xing Zuo
DOI: https://doi.org/10.1109/jsen.2022.3157260
IF: 4.3
2022-04-15
IEEE Sensors Journal
Abstract:In oil and gas development operation, for horizontal wells and extended reach wells, monitoring cuttings flow rate is an important method for analyzing wellbore cleanliness. However, due to complex working environment on site, the accuracy of cuttings flow rate monitoring is low. In order to solve this problem, based on the analysis of a cuttings flow rate real-time measurement method, combined with the classic Kalman filter (KF) algorithm, an adaptive KF model based on fuzzy control rules (Fuzzy-KF) is proposed, it realize real-time update of process noise <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="3.648ex" height="2.843ex" style="vertical-align: -0.838ex;" viewBox="0 -863.1 1570.5 1223.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMAIN-28" x="0" y="0"></use> <use xlink:href="#MJMATHI-51" x="389" y="0"></use> <use xlink:href="#MJMAIN-29" x="1181" y="0"></use></g></svg></span> and measurement noise <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="3.573ex" height="2.843ex" style="vertical-align: -0.838ex;" viewBox="0 -863.1 1538.5 1223.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMAIN-28" x="0" y="0"></use> <use xlink:href="#MJMATHI-52" x="389" y="0"></use> <use xlink:href="#MJMAIN-29" x="1149" y="0"></use></g></svg></span> and realize real-time correction of data collected by sensors of Cuttings Flow Meters (CFM). Through the comparison of experiments, the research results show that the mean square error (MSE) of the Fuzzy-KF model is 76.2919, and the posterior error estimate be less than 0.3, and all aspects of performance are better than the KF and Sage-Husa KF models. The effects of different initial values of <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.838ex" height="2.509ex" style="vertical-align: -0.671ex;" viewBox="0 -791.3 791.5 1080.4" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-51" x="0" y="0"></use></g></svg></span> and <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.764ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 759.5 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-52" x="0" y="0"></use></g></svg></span> on the experimental results were studied, the research result shows that the difference of the initial value of <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.838ex" height="2.509ex" style="vertical-align: -0.671ex;" viewBox="0 -791.3 791.5 1080.4" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-51" x="0" y="0"></use></g></svg></span> and <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.764ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 759.5 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-52" x="0" y="0"></use></g></svg></span> will affect the data correction result, but does not change the change trend of each parameter. The Fuzzy-KF model established in this paper can effectively reduce the environmental interference to CFM, and it provides new technical support for improving the accuracy of cuttings flow rate monitoring.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMAIN-28" d="M94 250Q94 319 104 381T127 488T164 576T202 643T244 695T277 729T302 750H315H319Q333 750 333 741Q333 738 316 720T275 667T226 581T184 443T167 250T184 58T225 -81T274 -167T316 -220T333 -241Q333 -250 318 -250H315H302L274 -226Q180 -141 137 -14T94 250Z"></path><path stroke-width="1" id="MJMATHI-51" d="M399 -80Q399 -47 400 -30T402 -11V-7L387 -11Q341 -22 303 -22Q208 -22 138 35T51 201Q50 209 50 244Q50 346 98 438T227 601Q351 704 476 704Q514 704 524 703Q621 689 680 617T740 435Q740 255 592 107Q529 47 461 16L444 8V3Q444 2 449 -24T470 -66T516 -82Q551 -82 583 -60T625 -3Q631 11 638 11Q647 11 649 2Q649 -6 639 -34T611 -100T557 -165T481 -194Q399 -194 399 -87V-80ZM636 468Q636 523 621 564T580 625T530 655T477 665Q429 665 379 640Q277 591 215 464T153 216Q153 110 207 59Q231 38 236 38V46Q236 86 269 120T347 155Q372 155 390 144T417 114T429 82T435 55L448 64Q512 108 557 185T619 334T636 468ZM314 18Q362 18 404 39L403 49Q399 104 366 115Q354 117 347 117Q344 117 341 117T337 118Q317 118 296 98T274 52Q274 18 314 18Z"></path><path stroke-width="1" id="MJMAIN-29" d="M60 749L64 750Q69 750 74 750H86L114 726Q208 641 251 514T294 250Q294 182 284 119T261 12T224 -76T186 -143T145 -194T113 -227T90 -246Q87 -249 86 -250H74Q66 -250 63 -250T58 -247T55 -238Q56 -237 66 -225Q221 -64 221 250T66 725Q56 737 55 738Q55 746 60 749Z"></path><path stroke-width="1" id="MJMATHI-52" d="M230 637Q203 637 198 638T193 649Q193 676 204 682Q206 683 378 683Q550 682 564 680Q620 672 658 652T712 606T733 563T739 529Q739 484 710 445T643 385T576 351T538 338L545 333Q612 295 612 223Q612 212 607 162T602 80V71Q602 53 603 43T614 25T640 16Q668 16 686 38T712 85Q717 99 720 102T735 105Q755 105 755 93Q755 75 731 36Q693 -21 641 -21H632Q571 -21 531 4T487 82Q487 109 502 166T517 239Q517 290 474 313Q459 320 449 321T378 323H309L277 193Q244 61 244 59Q244 55 245 54T252 50T269 48T302 46H333Q339 38 339 37T336 19Q332 6 326 0H311Q275 2 180 2Q146 2 117 2T71 2T50 1Q33 1 33 10Q33 12 36 24Q41 43 46 45Q50 46 61 46H67Q94 46 127 49Q141 52 146 61Q149 65 218 339T287 628Q287 635 230 637ZM630 554Q630 586 609 608T523 636Q521 636 500 636T462 637H440Q393 637 386 627Q385 624 352 494T319 361Q319 360 388 360Q466 361 492 367Q556 377 592 426Q608 449 619 486T630 554Z"></path></defs></svg>
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?