Optimization Analysis of the Staggered Herringbone Micromixer Based on the Slip-Driven Method
Honjun Song,Xie-Zhen Yin,Dawn J. Bennett
DOI: https://doi.org/10.1016/j.cherd.2008.03.015
IF: 7.8
2008-01-01
Process Safety and Environmental Protection
Abstract:In this paper the mixing effect of the staggered herringbone micromixer (SHM) was investigated by using the slip-driven method. This method simplified the 3D flow in the staggered herringbone micromixer into a 2D cavity flow with an axial Poiseuille flow. The solution of the 2D cavity flow was obtained by solving the biharmonic equation. An improved design with a cosine asymmetric factor P(z) was proposed, and its mixing effect was demonstrated by comparing the effect with the original design [Stroock, A.D., Dertinger, S.K.W., Ajdari, A., Mezic, I., Stone, H.A. and Whitesides, G.M., 2002, Chaotic mixer for microchannels, Science, 295: 647–651; Stroock, A.D., Dertinger, S.K.W., Whitesides, G.M. and Ajdari, A., 2002, Patterning flows using grooved surfaces, Anal Chem, 74: 5306–5312]. Four methods evaluating the mixing effect were used: (1) mixing images at different cycles; (2) Poincaré Sections; (3) segregation intensity and (4) stretching computation. Finally, an optimized value of P0=1/6 was obtained, and the mixing effect of the improved design for different P0 is discussed.