Evolution of Stability-Indicating Method in the Quantification of Related Substances and Degradation Products of Elagolix Sodium: Quality by Design-Driven Approach Utilizing Ultra-high Performance Liquid Chromatography

Sivaganesh Bommi,Subbalakshmi Jayanty,Satyanarayana Raju Tirumalaraju,Suresh Kola,Venkata Siva Rama Krishna Reddy Kallam
DOI: https://doi.org/10.1007/s10337-022-04223-2
2022-11-29
Chromatographia
Abstract:The development of a stability-indicating analytical method is a quantitative analytical method that can detect the change with time in the chemical or physical properties of specific drug substances so that the content of active ingredients and degradation products can be accurately measured without interference. However, regarding Elagolix sodium (ELX), analytical methods to quantify all its potential-related impurities along with its precursor intermediates used for the synthesis of ELX are yet unavailable. Hence, the proposed study provides a suitable analytical method, developed with quality by a design-driven approach utilizing the design of experiments. ELX is a specific type of receptor antagonist that acts upon hormone receptors, unlike accessible alternative drugs that fall under the opioid antagonist category. Therefore, in this article, a stability-indicating ultra-high performance liquid chromatographic (UHPLC) method is elaborated for the identification of related substances/impurity testing of ELX, besides employing quality by design (QbD) principles; associated with the analytical process development, which was proficient in the separation of nine potential ELX-related impurities. On a water X-select phenyl hexyl UHPLC column with gradient elution of 10 mM diammonium hydrogen orthophosphate as a mobile phase-A, pH was adjusted to 10.0; acetonitrile was taken as the mobile phase-B in a gradient elution mode at a flow rate 0.4 mL min –1 at 40 °C. This method was fully validated and found accurate within the range 91.8–107.2%, apparently precise with relative standard deviation 0.9% for ELX (1.2 mg mL –1 ) and 0.8–1.8% for its related impurities (0.0005 mg mL –1 ); also found linear, with correlation coefficient r ≥ 0.999. All impurities were found to have a limit of quantification (LOQ) at a level of 0.05% with respect to the test concentration of 1.2 mg mL –1 of ELX. Currently, the developed procedure reveals a good method operable design range (MODR) for the optimized experimental chromatographic conditions. Forced degradation of ELX carried under acidic, basic, and oxidative stressed conditions, demonstrated the method as a stability-indicating one.
chemistry, analytical,biochemical research methods
What problem does this paper attempt to address?