An eight-channel-based near infrared void fraction measurement system using T-ART algorithm

Lide Fang,Xinyue Yuan,Zhenyu Zhang,Cong Zhou,Honglian Li,Mingjing Chen,Kang Lan
DOI: https://doi.org/10.1016/j.optlaseng.2022.107385
IF: 5.666
2022-11-18
Optics and Lasers in Engineering
Abstract:The testing of gas-liquid two-phase flow parameters is of great importance for product quality assessment, cost reduction, and production safety. In this paper, an eight-channel array sensor is designed based on the principle of the near-infrared optical tomography system. The void fraction of the stratified flow was analysed based on Tikhonov for a priori information and Algebra Reconstruction Technique fusion (T-ART). and void fraction of the flow pattern measured by the algorithm is compared with the void fraction obtained by the Particle Image Velocimetry (PIV) technique. Finally, the void fraction was evaluated with type A evaluation of uncertainty and the result was 0.787±0.0964 indicating that the measurement results were accurate and reliable.
optics
What problem does this paper attempt to address?