Sorption-Fluorimetric Determination of Quinolones in Waste and Natural Waters with a Smartphone

V. G. Amelin,Z. A. Ch. Shogah,D. S. Bolshakov
DOI: https://doi.org/10.3103/S0027131421040027
2021-08-24
Moscow University Chemistry Bulletin
Abstract:A simple, affordable, and safe (green chemistry) method is proposed for determining 17 quinolone antibiotics in waste and natural waters by the sorption-fluorimetric method using a smartphone as an analyte signal recorder. The method is based on static sorption of quinolones by silica gel from aqueous solutions. When the sorbate is irradiated with ultraviolet light (365 nm), blue or turquoise fluorescence is observed, the intensity of which is measured with a smartphone. The values of the basic components of the RGB colorimetric system are used as an analytical signal, followed by the calculation of the final color. The limits of detection and quantification are 0.0007–0.004 and 0.002–0.01 μg/mL, respectively, for all analyzed analytes. The range of the determined contents is 0.002 (0.01)–0.2 μg/mL. A procedure for the determination of quinolones in waste and natural waters is proposed. The relative standard deviation of the analysis results does not exceed 0.2.
What problem does this paper attempt to address?