Accurate determination of stable silver isotopes in zinc-rich samples through effective separation of silver and zinc
Haotian Gong,Youqiang Qi,Ting-guang Lan,Haifeng Fan,Youwei Chen,Ting Zhou,Ruizhong Hu
DOI: https://doi.org/10.1039/d4ja00125g
2024-06-13
Journal of Analytical Atomic Spectrometry
Abstract:Silver isotopes have been extensively used in environment, archaeology, and economic geology. Nevertheless, accurate analysis of Ag isotope ratios faces challenges caused by the presence of matrix elements ( e.g. Zn, Cu, and Pb) in most sulfide samples due to isobaric and polyatomic interferences during multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) routines. Most of these elements, such as Cu and Pb, can be effectively removed after the first column through a tandem column setup. However, the complete removal of Zn from Ag remains a significant unresolved issue, particularly given their common coexistence in sulfide minerals. Combining previous studies and the chemical principle of ion exchange resin, we optimized a two-stage ion exchange procedure by meticulously adjusting solution volumes and the column separation process. A condensed Zn-doped NIST SRM (silver international standard reference material) 978a was tested for AG50W-X8 resin following our modified procedure, resulting in distinct elution curves of Ag and Zn. Subsequently, three sphalerite samples were selected for the optimized two-stage ion exchange procedure, and ICP-MS results of silver elution fractions demonstrated complete separation of Ag and Zn. The whole procedure achieved an Ag yield exceeding 98.1 ± 2.3% (2SD, n = 4). NIST SRM 978a and IAEA-S-1 (an in-house standard) were tested for long-term reproducibility with −0.001 ± 0.030‰ (2SD, n = 25) and 0.054 ± 0.023‰ (2SD, n = 22) of δ 109 Ag, respectively, indicating the high accuracy in MC-ICPMS routines. Zn-doped NIST SRM 978a and sphalerite samples were further subjected to the modified procedure, and they exhibited values of 0.004 ± 0.014‰ (2SD, n = 3) and −0.214 ± 0.033‰ (2SD, n = 12), respectively, for δ 109 Ag. Moreover, we selected eight sphalerite samples from several hypogene deposits in China and obtained δ 109 Ag values from −0.229‰ to 2.227‰, indicating the significant Ag isotopic fractionation between Ag-bearing and Zn-rich minerals in hypogene deposits. In conclusion, this study shows the feasibility of accurately measuring Ag isotopes in Zn-rich samples and reveals their application potential in related Ag-bearing and Zn-rich deposits.
spectroscopy,chemistry, analytical